This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Coriolis
-
Product headline
The highest capacity four‐tube flowmeter with custody transfer functionality. For highest flow rates and outstanding performance in on/offshore applications in the oil & gas industry.
-
Sensor features
Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 300 to 400 (12 to 16"). Four‐tube system with low pressure drop.
-
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 300 to 400 (12 to 16")
-
Wetted materials
Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.1 (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 4100 t/h (0 to 4520 tn. sh./h)
-
Max. process pressure
PN 100, Class 600
-
Medium temperature range
–50 to +180 °C (–58 to +356 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
phase‐shifted pulse
Relay -
Inputs
1 modular input: status
-
Digital communication
HART
Modbus RS485 -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, EAC
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, custody transfer, PED, CRN, AD 2000, NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME, NORSOK
-
Product safety
CE, C-tick, EAC marking
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer approvals: MI-005 (liquid) -
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
-
Measuring principle
Coriolis
-
Product headline
The highest capacity four‐tube flowmeter with custody transfer functionality. For highest flow rates and outstanding performance in on/offshore applications in the oil & gas industry.
-
Sensor features
Increased profit – single installation point providing premium accuracy for large quantities. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 300 to 400 (12 to 16"). Four‐tube system with low pressure drop.
-
Transmitter features
Quality – designed for custody transfer; featuring worldwide recognized metrological approvals. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 300 to 400 (12 to 16")
-
Wetted materials
Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.1 (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 4100 t/h (0 to 4520 tn. sh./h)
-
Max. process pressure
PN 100, Class 600
-
Medium temperature range
–50 to +180 °C (–58 to +356 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
phase‐shifted pulse
Relay -
Inputs
1 modular input: status
-
Digital communication
HART
Modbus RS485 -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, custody transfer, PED, CRN, AD 2000, NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME, NORSOK
-
Product safety
CE, C-tick, EAC marking
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer approvals: MI-005 (liquid) -
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
-
-
Technical Information (TI)
Proline Promass 84X Technical Information
-
Technical Information (TI)
English version - 02/2014New version available in EnglishCoriolis flowmeter
EN 27/02/201431/12/2011Language:
English
Version:
27/02/2014
File size:
2.2 MB
File name:
TI00111DEN_0214.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 84 HART Description of Device Functions
-
Operating Instruction (BA)
English version - 09/2008New version available in EnglishCoriolis Mass Flow Measuring System for Custody Transfer. Additional
documentation for Operating Instructions Promass 84.EN 01/09/200801/12/200601/03/2005Language:
English
Version:
01/09/2008
File size:
1.4 MB
File name:
BA110DEN_0908.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 84 Modbus RS485 Operating Instructions
-
Operating Instruction (BA)
English version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System for Custody Transfer. The
description of the device functions are in a separate documentation.EN 15/10/201231/12/201108/06/201001/11/200801/12/2006Language:
English
Version:
15/10/2012
File size:
2.4 MB
File name:
BA00129DEN_1412.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 84 HART Operating Instructions
-
Operating Instruction (BA)
English version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System for Custody Transfer. The
description of the device functions are in a separate documentation.EN 15/10/201231/12/201101/11/200801/12/200601/03/2005Language:
English
Version:
15/10/2012
File size:
2.2 MB
File name:
BA00109DEN_1412.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 84 MODBUS RS485 Description of Device Functions
-
Operating Instruction (BA)
English version - 11/2008New version available in EnglishCoriolis Mass Flow Measuring System for Custody Transfer. Additional
documentation for Operating Instructions Promass 84.EN 01/11/200801/12/2006Language:
English
Version:
01/11/2008
File size:
1.5 MB
File name:
BA130DEN_1108.pdf
-
-
-
Short Instruction (KA)
Proline Promass 84 Brief Operating Instructions
-
Short Instruction (KA)
English version - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System
EN 15/10/201231/12/201101/07/2007Language:
English
Version:
15/10/2012
File size:
671.5 KB
File name:
KA00025DEN_1412.pdf
-
-
-
Installation Instructions (EA)
Replacing Power supply and display Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN 15/11/201818/11/2011Language:
English
Version:
15/11/2018
File size:
455.1 KB
File name:
EA00063DA2_1518.pdf
-
-
-
Installation Instructions (EA)
Replacing connecting cable Installation Instructions
-
Installation Instructions (EA)
English version - 10/2018New version available in EnglishPromass 60, 63, 64, 80, 83, 84
EN 01/10/201801/12/2009Language:
English
Version:
01/10/2018
File size:
293.1 KB
File name:
EA00081DA2_1218.pdf
-
-
-
Installation Instructions (EA)
EA Replacing cover and O-ring
-
Installation Instructions (EA)
English version - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN 15/10/202401/10/201828/06/2012Language:
English
Version:
15/10/2024
File size:
797.3 KB
File name:
EA00098DA2_1624-00.pdf
-
-
-
Installation Instructions (EA)
Replacing interface parts Installation Instructions
-
Installation Instructions (EA)
English version - 04/2019New version available in EnglishPromass 40, 80, 83, 84, Cubemass 8CN, CNGmass 8DF
EN 01/04/201917/11/2011Language:
English
Version:
01/04/2019
File size:
787.5 KB
File name:
EA00036DA2_1519.pdf
-