This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Electromagnetic
-
Product headline
The flowmeter for smallest flow rates with flexible system integration. For demanding hygienic applications.
-
Sensor features
Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG).
-
Transmitter features
Quality – software for filling & dosing, density, electrode cleaning and also advanced diagnostics. Easy calculation – bidirectional totalizers. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 2...150
1/12"...6" -
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum -
Measured variables
Volume flow
-
Max. measurement error
±0.2%
-
Measuring range
0...600 m3/h
-
Max. process pressure
PN16 to 40
-
Medium temperature range
-20...+150°C
(-4...+302°F) -
Ambient temperature range
-20...+60°C
-40...+60°C (optional) -
Degree of protection
IP 67 (NEMA 4x)
-
Display/Operation
Four line display with backlit
Touch control -
Outputs
4...20 mA
Pulse / frequency(active/passive)
Relais
Status -
Inputs
Status
Current input -
Digital communication
HART
PROFIBUS PA
Profibus DP
FOUNDATION Fieldbus -
Hazardous area approvals
ATEX, FM, CSA
-
Product safety
CE, C-tick, EAC marking
-
Hygienic approvals and certificates
3-A, EHEDG
-
-
Technical Information (TI)
Promag 50H, 53H Karta katalogowa
-
Technical Information (TI)
Polish version - 05/2012New version available in EnglishPrzepływomierz elektromagnetyczny do pomiaru przepływu cieczy w
przemyśle spożywczym, farmaceutycznym, instalacjach higienicznych i
procesowych.Language:
Polish
Version:
01/05/2012
File size:
1.3 MB
File name:
Ti00048dpl_1312.pdf
-
-
-
Operating Instruction (BA)
Készülékfunkciók leírása PROline promag 53
-
Operating Instruction (BA)
Hungarian version - 06/2001New version available in EnglishElektromágneses áramlásmérõ rendszer
Language:
Hungarian
Version:
01/06/2001
File size:
2.4 MB
File name:
Promag53_BA048DHU.pdf
-
-
-
Operating Instruction (BA)
Przep³ywomierz Elektromagnetyczny promag 53
-
Operating Instruction (BA)
Polish version - 03/2005New version available in EnglishInstrukcja obs³ugi
EN 01/03/2005Language:
Polish
Version:
01/03/2005
File size:
3.3 MB
File name:
Ba047dpl.pdf
-
-
File size:
File name:
-
File size:
File name:
-
-
General Station Description (GSD)
General Station Description (GSD) - PROMAG 53 PBUS - PROFIBUS DP
-
General Station Description (GSD)
Language neutral - 04/2014New version available in EnglishAny, PROFIBUS System, Any
Language:
Language neutral
Version:
17/04/2014
File size:
45.4 KB
File name:
EH_DP_FL_Promag_0x1526_V01_01_00_DPLIB.zip
-
-
-
General Station Description (GSD)
General Station Description (GSD) - PROMAG 53 PBUS - PROFIBUS PA
-
General Station Description (GSD)
Language neutral - 02/2015New version available in EnglishAny, PROFIBUS System, Any
Language:
Language neutral
Version:
18/02/2015
File size:
6 MB
File name:
EH_PA_FL_Promag_0x1527_V02_02_xx_PALIB.zip
-
-
-
General Station Description (GSD)
General Station Description (GSD) - PROMAG 53 PBUS - PROFIBUS DP
-
General Station Description (GSD)
Language neutral - 04/2014New version available in EnglishAny, PROFIBUS System, Any
Language:
Language neutral
Version:
17/04/2014
File size:
45.5 KB
File name:
EH_DP_FL_Promag_0x1526_V02_01_00_DPLIB.zip
-
-
-
General Station Description (GSD)
General Station Description (GSD) - PROMAG 53 PBUS - PROFIBUS DP
-
General Station Description (GSD)
Language neutral - 04/2014New version available in EnglishAny, PROFIBUS System, Any
Language:
Language neutral
Version:
17/04/2014
File size:
1.3 MB
File name:
EH_DP_FL_Promag_0x1526_V02_03_00_DPLIB.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - PROMAG 53 - HART
-
Electronic Device Description (EDD)
Language neutral - 08/2015New version available in EnglishSIEMENS, PDM, 8.2 SP 1
SIEMENS, PDM, 6.0 SP5
SIEMENS, PDM, 6.1Language:
Language neutral
Version:
04/08/2015
File size:
74.1 KB
File name:
EH_HART_FL_Promag_0x0042_0x08_0x02_PDM.zip
-