Radiometric level and density measurement Gammapilot FMG50
Compact transmitter for point level detection, continuous level, interface and density measurement
The Gammapilot FMG50 compact transmitter is designed for non-contact point level detection, continuous level, interface and density measurement in liquids, solids, suspensions or sludges. As the first true 2-wire loop powered compact transmitter it minimizes engineering and installation efforts.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Process temperature
Any
-
Process pressure absolute / max. overpressure limit
Any
-
Max. measurement distance
Unlimited measuring range,
Cascade -
Accuracy
+/-1%
-
Main wetted parts
Non-contact
-
Quick selection
Individual configuration
-
Benefits
First real 2-wire loop-powered compact transmitter minimizes engineering and installation efforts
Reduced installation and engineering costs thanks to the first 2-wire loop powered compact transmitter
Increased plant safety, efficiency and availability...
-
Field of application
For all kinds of process vessels, like reactors, autoclaves, separators, acid tanks, cyclones
For liquids, solids, suspensions or sludges etc.
Extreme measuring conditions, for example corrosion, abrasion, viscosity, toxicity
Process temperature: No...
Documents / Manuals / Software
-
Gammapilot FMG50
Radiometric measurement
Technical Information (TI) -
Gammapilot FMG50
Operating Instructions
Radiometric measurement
Operating Instruction (BA) -
Gammapilot FMG50
Radiometric measurement
Device Parameter (GP) -
Gammapilot FMG50
Radiometric measurement
Short Instruction (KA)12/20English -
HAN7D plug, 90 deg, housing side
HAN7D socket, cable side
Gammapilot, Cerabar, Deltabar
Installation Instructions (EA) -
Segment display VU100/with Bluetooth VU101
Graphical display VU112/with Bluetooth VU113
Gammapilot FMG50
Cerabar PMC51B, PMP51B, PMC71B, PMP71B
Deltabar PMD55B, PMD75B, PMD78BInstallation Instructions (EA) -
Cover, cover seal
Liquiphant FTL41, FTL51B, FTL62, FTL64
Gammapilot FMG50
Cerabar PMC51B, PMP51B, PMC71B, PMP71B
Deltabar PMD55B, PMD75B, PMD78BInstallation Instructions (EA) -
HistoROM
Gammapilot FMG50
Cerabar PMC71B, PMP71B
Deltabar PMD75B, PMD78B
Liquiphant FTL51B, FTL62, FTL64Installation Instructions (EA) -
Ground terminal
Liquiphant, Gammapilot,
Cerabar, DeltabarInstallation Instructions (EA) -
Electronics module, HART, FMG50
Installation Instructions
Gammapilot FMG50
Installation Instructions (EA) -
Photomultiplier FMG50
Gammapilot FMG50
Installation Instructions (EA) -
Dummy plug M20×1.5, dummy plug NPT½
Liquiphant, Gammapilot,
Cerabar, Deltabar
Prothermo NMT81Installation Instructions (EA) -
Single compartment housing, dual compartment housing
Cerabar, Deltabar
GammapilotInstallation Instructions (EA) -
PVT scintillator
Gammapilot FMG50
Installation Instructions (EA) -
Sensor electronics module FMG50
Gammapilot FMG50
Installation Instructions (EA) -
M12 plug (housing side)
Liquiphant, Gammapilot,
Cerabar, DeltabarInstallation Instructions (EA) -
Cable gland M20x1.5
Liquiphant, Gammapilot
Cerabar, DeltabarInstallation Instructions (EA) -
Terminal module, 4 to 20 mA
Gammapilot FMG50, Prothermo NMT81
Cerabar PMC71B, PMP71B
Deltabar PMD75B, PMD78B
Liquiphant FTL51B, FTL62, FTL64Installation Instructions (EA) -
Mounting clamp
80 mm, 95 mm
Installation Instructions
Gammapilot FMG50
Installation Instructions (EA) -
NaI scintillator
Gammapilot FMG50
Installation Instructions (EA) -
Gammapilot FMG50
4-20 mA HART
Ex db ia IIC T6...T1 GbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
ATEX:
II 2 D Ex tb IIIC T85°C Db
IECEx:
Ex tb IIIC T85°C DbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
ATEX:
II 2 G Ex db IIC T6...T1 Gb
IECEx:
Ex db IIC T6...T1 GbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex tD A21 IP66/IP68 T85°CEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex db ia IIC T6...T1 GbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex d ia IIC T1-T6 GbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Control Drawing IS / Div. 2Ex Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex d IIC T1-T6 GbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex db IIC T6...T1 GbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex tb IIIC T85°C DbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex db IIC T6...T1 GbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Ex tb IIIC T85°C DbEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
Control Drawing XPEx Safety Instructions (XA) -
Gammapilot FMG50
4-20 mA HART
ATEX:
II 2 G Ex db ia IIC T6...T1 Gb
IECEx:
Ex db ia IIC T6...T1 GbEx Safety Instructions (XA) -
Gammapilot FMG50
Allgemeine bauaufsichtliche Zulassung /
Allgemeine Bauartgenehmigung
Z-65.15-603Certificate (ZE) -
Heat shield for Gammapilot FMG50
Radiometric measurement
Special Documentation
Heat shield for Gammapilot FMG50
Special Documentation (SD) -
Mounting device for Gammapilot FMG50
Radiometric measurement
Special Documentation
Mounting device for Gammapilot FMG50
Special Documentation (SD) -
Cable gland M20 Ex d
for the Japanese market
Special Documentation (SD) -
Gammapilot FMG50
HART
Application package
Heartbeat Verification + Monitoring
Special Documentation
Radiometric measurement
Special Documentation (SD) -
Weather protection cover
for dual compartment housing
Accessories
Special Documentation (SD) -
VU101 Bluetooth® display
Remote operation via Bluetooth® wireless technology
Special Documentation (SD) -
M12 socket
Accessories for Liquipoint, Liquitrend, Liquiphant, Ceraphant, Cerabar,
Deltabar, GammapilotSpecial Documentation (SD) -
Adapter/cable gland
Level measurement, pressure measurement
Special Documentation (SD) -
Gammapilot FMG50
Radiometric measurement
Functional Safety (FY)12/20English -
Ensuring higher availability in cement plants
Ensuring higher availability in cement plants
with continuous blockage detection using radiometric measurementPublications (PU)08/19English -
Publicación: Maximizando la eficiencia y minimizando costos en una
Unidad
Coquizadora Retardada
Usando la medición de nivel continuo con tecnología radiométrica.
Publications (PU)02/20Spanish -
Publications: Maximising throughput and minimizing costs in a delayed
coker unit
Using radiometric measurement for continuous level measurement
Publications (PU)02/20English -
Radiometric detection of deposits in cyclones
Radiometric detection of deposits in cyclones at Holcim Schweiz AG.
Case Studies (CS)12/20English -
Ansatzmessung im Zyklon
Ansatzmessung im Zyklon eines Zementwerks mit dem Gammapilot FMG50
Case Studies (CS)07/20German -
White Paper: Density measurement under all circumstances
Density measurement under all circumstances
with highly available and reliable radiometric measurementCase Studies (CS)06/20German -
White Paper: Density measurement under all circumstances
Density measurement under all circumstances
with highly available and reliable radiometric measurementCase Studies (CS)06/20English -
Innovation 2-pager Gammapilot FMG50
As the first 2-wire loop-powered compact transmitter, the Gammapilot
FMG50 fits into a wide range of applications.Innovations (IN)03/19English -
Innovation 2-Seiter Gammapilot FMG50
Als erster Zweileiter-Kompakttransmitter passt der Gammapilot FMG50 in
eine Vielzahl von Anwendungen.Innovations (IN)03/19German -
EDD Single, PDM_HART_LE_Gammapilot_0x1130_0x01_0x02, 27.02.2020 (Level, Gammapilot, 0x1130)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_LE_Gammapilot5x_0x1130_0x01_0x01, 07.02.2020 (Level, Gammapilot, 0x1130)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0, 14.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_LE_Gammapilot_0x1130_0x01_0x01, 04.10.2019 (Level, Gammapilot, 0x1130)
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_LE_Gammapilot5x_0x1130_0x01_0x01, 16.09.2019 (Level, Gammapilot, 0x1130)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Gammapilot_FMG50_HART_FW01_00_zz_Dev_Rev_01, 06.11.2020 (Level, Gammapilot, 0x1130)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTwareVersion: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.43.0.1953Language neutral -
Faceplate Single, PRM_HART_LE_Gammapilot_0x1130_0x01_0x02, 18.02.2020 (Level, Gammapilot, 0x1130)
HART,
Plant Resource Manager Version: R4.02Faceplate1.00.00Language neutral -
Gammapilot
Product Code: FMG50-
Declaration Number: EC_00821_01.20EU DeclarationGerman , English , fr -
Gammapilot
Product Code: FMG50-
Declaration Number: SIL_00340_01.19SIL DeclarationEnglish -
Gammapilot
Product Code: FMG50-
Region/Country: Japan
Approval Agency: CML
Protection: Ex d [ia] IIC T6...T1 Gb, Ex tb IIIC Db, Ex db IIC T6...T1 GbExplosion ProtectionEnglish -
Gammapilot
Product Code: FMG50-
Region/Country:
Approval Agency:
Protection: Ex ia, Ex tb, Ex dbExplosion Protection -
Gammapilot
Product Code: FMG50-
Region/Country: Canada, USA
Approval Agency: CSA
Protection: DIP, IS, NI, XPExplosion ProtectionEnglish -
Gammapilot
Product Code: FMG50-
Region/Country: International (IECEx)
Approval Agency: BV
Protection: Ex ia, Ex tb, Ex dbExplosion ProtectionEnglish -
Gammapilot
Product Code: FMG50-
Region/Country: Europe (ATEX)
Approval Agency: BV
Category: II 2 D, II 2 G
Protection: Ex ia, Ex tb, Ex dbExplosion ProtectionGerman , English -
Gammapilot
Product Code: FMG50-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex d IIC T6...T1 Gb, Ex d [ia] IIC T6...T1 Gb, Ex tb IIIC DbExplosion ProtectionPortuguese -
Gammapilot
Product Code: FMG50-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex d, Ex tD, Ex d iaExplosion ProtectionChinese -
Gammapilot
Product Code: FMG50-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.15-603Overfill PreventionGerman -
Gammapilot
Product Code: FMG50-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)English -
Gammapilot
Product Code: FMG50-
Region/Country: Canada, USA
Approval Agency: CSAOrdinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Order code 71009287
-
Order code 71435116
Cover, Alu, closed
Sealing ring, HNBR. Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B,PMP51B, PMP71B.
-
Order code 71435118
Cover, Alu, closed, Ex d
Sealing ring, HNBR. Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71435121
Cover, Alu, connection compartment, Ex d
Sealing ring, HNBR. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71435122
Cover, 316L, closed, Ex d
Sealing ring, HNBR. Usage: FMG50, FTL51B, FTL62/64, PMD75B/PMD78B, PMC71B, PMP71B.
-
Order code 71435123
Cover, 316L, sight window, Ex d
Sealing ring, HNBR. Usage: FMG50, FTL51B, FTL62/FTL64, PMD75B/PMD78B, PMC71B, PMP71B.
-
Order code 71435128
Cover, 316L, connect. compartment, Ex d
Sealing ring, HNBR. Usage: FMG50, PMD75B/PMD78B, PMC71B, PMP71B.
-
Order code 71439085
Cover, Alu, connection compartment
Sealing ring, HNBR. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71439086
Cover red, Alu, closed, Ex d
Sealing ring, HNBR. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP1B, PMP71B.
-
Order code 71439087
Cover red, Alu,connect. compartment,Ex d
Sealing ring, HNBR. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71439088
Cover red, Alu, sight window, Ex d
Sealing ring, HNBR. Material sight window: borosilicat. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71439089
Cover, Alu, sight window
Sealing ring, HNBR. Material sight window: plastic. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71439090
Cover, Alu, sight window, Ex d
Sealing ring: HNBR. Material sight window: borosilicat. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71435132
-
Order code 71435135
Cable gland M20, plastic
Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71435136
Cable gland M20, brass nickel plated
Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71435137
Cable gland M20, 316L
Usage: FMG50, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 52006263
M12-female plug connector, cable side
M12 plug socket, cable side Self confectionery connection. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FTL31/FTL33, FTW23, FTW33,PMP11, PMP21, PMP51, PTC31B, PTP31B, QMW43.
-
Order code 71114212
M12-female plug connec.,90deg,cable side
Self confectionery connection. Usage: M12 plug socket, cable side.
-
Order code 71435138
M12 plug,CuZn-nickel plated,housing side
Usage: M12 screw-in thread, brass nickel plated, FMG50, FTL51B, FTL62/FTL64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B,PMP51B, PMP71B.
-
Order code 71439098
HAN7D plug, 90deg, housing side
Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71487198
Blind plug, M20, 316L, o-ring EPDM
Consists of: blind plug, o-ring PTFE coated 17.0x2.0. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B, NMT81.
-
Order code 71487199
Blind plug, M20, Alu, o-ring EPDM
Consists of: blind plug, o-ring PTFE coated 17.0x2.0. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B, NMT81.
-
Order code 71487201
Blind plug, NPT1/2, Alu
Consists of: blind plug, PTFE coated. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71487203
Blind plug, NPT1/2, 316L
Consists of: blind plug, PTFE coated. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B, NMT81.
-
Order code 71435766
-
Order code 71435767
Terminal unit TU101B, 4-20mA, OVP
Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71435772
Segment display VU100
W/o buttons. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B, NMT81.
-
Order code 71435779
Segment display + Bluetooth VU101
W/o buttons. Usage: FMG50, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.
-
Order code 71435787
-
Order code 71438555
-
Order code 71325082
Remote display RIA15, non Ex, plastic